Many thanks to every one who replied, the builtin LSI controller does not show any progress indicator when syncing disks, ie '% complete'; there is no extra arg to the 'raidctl' cmd that will cause a progress indicator to be displayed. only two of the four internal disks can be mirrored with the builtin hardware RAID controller, the other 2 internal disks can be mirrored with SVM. George On Mon, 15 Aug 2005 11:29:33 -0400 (EDT), George Kahler <george@yorku.ca> wrote: > I have bunch of newly bought V440 servers and am keen on using the > Hardware Mirroring feature. > > One thing I have noticed that there does not seem to be any indication > of a progress when rebuilding/syncing the disks. > > Q: > o does anyone know where I can get more information on this > hardware feature ? > > o is there a way to see the progress when it is syncing disks ? > > o after a server is built and mirroring is active, can one disk > be pulled out and used in another server as a base for that new > system ? I've been doing this with DiskSuite for some time now but > an not sure how this will work under hardware mirroring. > > o does anyone have any good or bad things that in regards to > hardware mirroring that might help me ? > > Thanks. > George _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Fri Sep 2 11:36:27 2005