Thanks to: Rick von Richter" <rick@vonr.net> Chris_Sellers@adp.com here are the comments: Have you tried clearing the bootprom to factory defaults? I.e. Hold down L1-N while powering up? Sounds like a power problem. I would follow Sun's recommendation - you may not be supplying enough AMPs to the unit. I was unable to resolve the problem yet. Vendor has indicated the centerplane is the problem. So replacing the centerplane is current approach. ssefoen ----------------------------------- Original question: To All Helpers: Upon booting an used V880 just received from vendor, the system fault LED light is solid Amber after turning on the power. The system shows: Error: Faulty Power Up Reset Sequence H/W under test = Safari bus CPU 1, motherboard/centerplane Repair instructions: Replace item in order listed by 'H/W under test' above END-error CPU 1 Trap trace The error message continue on all four CPUs. Then show a list of debug menu: 0 peek/poke interface 1 Dump DAR error bits ... d Do soft reset ? Help ____________________________________________________ Start your day with Yahoo! - make it your home page http://www.yahoo.com/r/hs _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Mon Aug 15 13:43:03 2005
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:50 EST