Many thanks to Eugene, Chris Ruhnke, and Joe Fletcher. The problem was probably caused by a bad connection, possibly at the terminator. I took the system down today and, since I had another tape device that I wanted to connect, I tried connecting it and I also removed and reattached the terminator of the device that had been causing problems. It seems there are no problems with the SCSI card as everything was visible in probe-scsi-all, boot -r went smoothly and I am able to use the device connected to the SCSI card I had been concerned about. Here is the advice I received: >From Joe: Try just replacing the terminator first. >From Eugene: Yes, a bad connection, or even a badly seated card can cause this. (Resolved such an issue at a client this week). It "could" be the card fault, but needs verification. It it later does proove to be the issue, I would not use it in a sensitive area (mission critical). What I suggest is use another SCSI device and cable (and terminator) on this card to verify, using a known good cable,device (and terminator if applicable. Remember, the Sun internal terminators are normally of a higher quality than the external ones) Also ensure it is all the same SCSI protcol (Single ended, High Voltage diffrential or LVD, as the case may be) old cable by putting it back (check pins carefully beforehand) old terminator if applicable by putting it back.(check pins carefully beforehand) If all works, was most likely a bad connection. End of process for above If the problems reappears, I would start by reseating the card and re-check. Try another slot for the card or another card in same slot. The idea is to get a know good working state, then replacing the suspect items one by one and rechecking. This way, as soon as a problem re-appears, we know we have a faulty item and can zoom in. Also, check the other components. Multi failures,though uncommon, has unfortunately caused a lot of false diagnosis. It is better to complete the process. The process is not too long on a small system which boots fast and can be done in an hour, as in your case. Big systems are what normally what bites :-) >From Chris: YES, the problem could be a loose (or bad) cable; but it could also be the card. The only way I know of to tell for sure is to swap cables. You have 2 cards -- call 'em A1 and A2 (adapter 1 and 2) -- original hunh? Each card has two cables -- call 'em A1C1 and A1C2 for adapter A1 and A2C1/A2C2 for adapter A2. >From your problem statement, your internal disk(s) are connected to A1C1 and the failures/errors occurred on A1C2. Your tape drive is now connected to A2C2 (I'm guessing at the cable, adjust as appropriate). Without changing anything else -- i.e. don't touch any other connections -- you need to: - shutdown your system - open the chassis - swap the cables A1C2 and A2C2 at the adapter cards - reboot If the errors return, your problem is with the adapter card and you should consider replacing it. If there are no errors, connect the tape drive back to A2C2 (the former A1C2) and reboot. If there are still no errors, your problem may have been a loose connection at the adapter A1 -- but keep an eye on things for a while. If the problems do return, you probably have a bad cable. If different problems assert themselves -- welcome to the world of hardware triage! When you are done, put things back the way they were when you started to avoid confusion later. -----Original Message----- From: RUSSELL, Marian Sent: Wednesday, 09 March, 2005 08:25 Subject: SCSI bus reset I have a SUNBlade 100 with two Ultra-SCSI cards. The backups to the tape drive (Exabyte 8505) on my system have been failing for the last couple of days. I had thought the tape drive was perhaps defective because it is old, and since I have an extra tape drive, I tried this morning to replace the current drive with the spare one. When I rebooted after exchanging the drives, I got error messages like : Target 3 reducing sync transfer rate, got SCSI bus reset, and Target 3 reverting to async mode. I did a search and found in SUN that perhaps the problem is with the SCSI card and not the tape drive, so I tried connecting the drive to the other SCSI card and everything was fine - no error messages and the drive is happily now tarring the latest set of backup files to tape. Since one of our disk packs is connected to the other half of this card, I am concerned that these error messages could indicate looming failure of the whole card. If one half of the card is defective, will the other half soon fail? Could something like a loose cable have caused the error messages? Is there any possibility that this SCSI card can be saved, or do I need to replace it ASAP? I would be very grateful for any advice. Thanks in advance. Marian Russell This email message is intended only for the use of the named recipient. Information contained in this email message and its attachments may be privileged, confidential and protected from disclosure. If you are not the intended recipient, please do not read, copy, use or disclose this communication to others. Also please notify the sender by replying to this message and then delete it from your system. _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Mon Mar 14 01:24:52 2005
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:44 EST