Summary - E450 Worrying Message - Part 2.

From: Nick Pettefar <Nick_at_Pettefar.com>
Date: Wed Nov 17 2004 - 16:41:55 EST
After a bit of swapping back and forth I have now logged a call with Sun.
It seems that my processors are OK but that the slot is not working!

I enabled maximum diagnostics in the OBP and any processor board plugged
into slot 3 fails the POST.  Move the processor into another slot and it works.

Regards,

Nick 
> 
> Hi, does anyone know what this message means? :
> 
> Failed Field Replaceable Units (FRU) in System:
> ==============================================
> SUNW,UltraSPARC-II unavailable :
>         PROM fault string: fail-Disabled by Command
>         Failed Field Replaceable Unit is UltraSPARC module Module 3
> 
> Regards,
> 
> Nick
> 