Thank you Tim and Ghassan Qanzu'a for your responses. Task : Changed a failed disk drive in a RAID 1+0. Here the logical drive status was DRV FAILED and disk status was BAD. StorEdge 3310. Intially Sun said to go ahead,pop in the new drive and rescan it. But later they send me a document which has a different procedure for each combination of logical drive and physcial drive conditioin and RAID in which it is. There are atleast 10 different procedures outlined.I think this document is not accessible to everyone. For example in my case the logical drive status was DRV FAILED adn disk status was BAD so I had to 1)enable periodic drive check time 2)POP in the new drive. 3) scan the new drive 4)and rebuild the target logical drive to which failed drive belongs. 5) disable periodic check time. 4th step in my case (70Gb each disk) took around 3 hours of time. If anyone wants this document in future contact me sreeredhat@yahoo.com Document Title: StorEdge_3310_FRU_replacement checklist.39a.pdf Thank you, Sree. __________________________________ Do you Yahoo!? Yahoo! Mail - Helps protect you from nasty viruses. http://promotions.yahoo.com/new_mail _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Mon Oct 11 10:17:04 2004
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:38 EST