Hi agn, and thanks to ponder@discworld.be, David Loesche (DLoesche@yipes.com), Scott Beardsley (thebofh@gmail.com), Gary Law (shunhelp1@lycos.com) and Michael Schulte (msu.linux@gmx.de) for responding to my question. Hmm, most of you suggested to detach and re-attach the mirror, or try to enable the second mirror first. I did this, and even deleted the entire mirror, updated /etc/vfstab and /etc/system to tell the machine to boot from the original disk, re-booted it, and created the mirrors again from scratch. Unfortunately, nothing helped me out... So, I've issued a maintenance window for tomorrow evening. I will try to shutdown the machine to single-user, and fsck the device to get rid of the errors. Let's hope I get it workin' again, if not, I will have to recover from backup. Thanks to all, have a nice hackin', Harald On Mon, 2004-08-16 at 13:39, Harald Husemann wrote: > Hi gurus, > > I have a big problem here with Solaris Volume Manager on a V240, running > Sol. 9. > > One of the mirrors (unfortunately the root-mirror...) is in > maintenance-state: > > root@plato # metastat d10 > d10: Mirror > Submirror 0: d11 > State: Needs maintenance > Submirror 1: d12 > State: Needs maintenance > Pass: 1 > Read option: roundrobin (default) > Write option: parallel (default) > Size: 62211726 blocks (29 GB) > > d11: Submirror of d10 > State: Needs maintenance > Invoke: after replacing "Maintenance" components: > metareplace d10 c1t0d0s0 <new device> > Size: 62211726 blocks (29 GB) > Stripe 0: > Device Start Block Dbase State Reloc Hot Spare > c1t0d0s0 0 No Last Erred Yes > > > d12: Submirror of d10 > State: Needs maintenance > Invoke: metasync d10 > Size: 62211726 blocks (29 GB) > Stripe 0: > Device Start Block Dbase State Reloc Hot Spare > c1t1d0s0 0 No Okay Yes > > > Device Relocation Information: > Device Reloc Device ID > c1t0d0 Yes id1,sd@SSEAGATE_ST336607LSUN36G_3JA7CQQX0000743600J4 > c1t1d0 Yes id1,sd@SSEAGATE_ST336607LC______3JA14LFQ00007311AATB > > Okay, I tried a metareplace: > > root@plato # metareplace -e d10 c1t0d0s0 > metareplace: plato: d10: c1t0d0s0: component in invalid state to replace > - Replace "Maintenance" components first > > root@plato # > > Hm, well, the the metasync first. The sync starts, and after syncing > abt. 8%, it stops without any message. > > I hope, anyone out there has an idea what I can do to fix this?? It's a > productive machine, so rebooting it would not be a good idea... > > Thanks a lot, > > Harald _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Mon Aug 16 11:11:20 2004
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:37 EST