Summary: Problem with LVM: Both submirrors "need maintenance"

From: Harald Husemann <harald.husemann_at_materna.de>
Date: Mon Aug 16 2004 - 11:11:29 EDT
Hi agn,

and thanks to ponder@discworld.be, David Loesche (DLoesche@yipes.com),
Scott Beardsley (thebofh@gmail.com), Gary Law (shunhelp1@lycos.com) and 
Michael Schulte (msu.linux@gmx.de) for responding to my question.
Hmm, most of you suggested to detach and re-attach the mirror, or try to
enable the second mirror first. I did this, and even deleted the entire
mirror, updated /etc/vfstab and /etc/system to tell the machine to boot
from the original disk, re-booted it, and created the mirrors again from
scratch.
Unfortunately, nothing helped me out...
So, I've issued a maintenance window for tomorrow evening. I will try to
shutdown the machine to single-user, and fsck the device to get rid of
the errors.
Let's hope I get it workin' again, if not, I will have to recover from
backup.

Thanks to all,

have a nice hackin',

Harald  

On Mon, 2004-08-16 at 13:39, Harald Husemann wrote:
> Hi gurus,
> 
> I have a big problem here with Solaris Volume Manager on a V240, running
> Sol. 9.
> 
> One of the mirrors (unfortunately the root-mirror...) is in
> maintenance-state:
> 
> root@plato # metastat d10
> d10: Mirror
>     Submirror 0: d11
>       State: Needs maintenance
>     Submirror 1: d12
>       State: Needs maintenance
>     Pass: 1
>     Read option: roundrobin (default)
>     Write option: parallel (default)
>     Size: 62211726 blocks (29 GB)
> 
> d11: Submirror of d10
>     State: Needs maintenance
>     Invoke: after replacing "Maintenance" components:
>                 metareplace d10 c1t0d0s0 <new device>
>     Size: 62211726 blocks (29 GB)
>     Stripe 0:
>         Device     Start Block  Dbase        State Reloc Hot Spare
>         c1t0d0s0          0     No      Last Erred   Yes
> 
> 
> d12: Submirror of d10
>     State: Needs maintenance
>     Invoke: metasync d10
>     Size: 62211726 blocks (29 GB)
>     Stripe 0:
>         Device     Start Block  Dbase        State Reloc Hot Spare
>         c1t1d0s0          0     No            Okay   Yes
> 
> 
> Device Relocation Information:
> Device   Reloc  Device ID
> c1t0d0   Yes    id1,sd@SSEAGATE_ST336607LSUN36G_3JA7CQQX0000743600J4
> c1t1d0   Yes    id1,sd@SSEAGATE_ST336607LC______3JA14LFQ00007311AATB
> 
> Okay, I tried a metareplace:
> 
> root@plato # metareplace -e d10 c1t0d0s0
> metareplace: plato: d10: c1t0d0s0: component in invalid state to replace
> - Replace "Maintenance" components first
> 
> root@plato #
> 
> Hm, well, the the metasync first. The sync starts, and after syncing
> abt. 8%, it stops without any message.
> 
> I hope, anyone out there has an idea what I can do to fix this?? It's a
> productive machine, so rebooting it would not be a good idea...
> 
> Thanks a lot,
> 
> Harald