SUMMARY: Sans on V440

From: Wolfgang Schwurack <wolf_at_uen.org>
Date: Fri Aug 06 2004 - 10:20:46 EDT
I just want to say thanks to all that replied.

 Here are the steps

download SAN_4.2a_install_it.tar.Z
zcat SAN_4.2a_install_it.tar.Z |tar xvf -
cd SAN_4.2a_install_it/
./install_it
reboot -- -r

When server comes up then follow the next steps

devfsadm -v
luxadm -e port
luxadm -e dump_map /devices/pci@1c,600000/SUNW,qlc@1/fp@0,0:devctl
cfgadm -l
cfgadm -c configure cX (X=container ID)


Wolfgang Schwurack wrote:

> Hi  All
>
> PROBLEM DESCRIPTION:
> Can not see StorEdge 3510 from OS. I am current on all patches. I 
> installed san software SAN_4.2a_install_it. At the ok prompt I type in 
> probe-scsi-all I get this, which see the storedge 3510
>
> /pci@1d,700000/SUNW,qlc@1
> *************************  Fabric Attached Devices  
> ************************
> Adapter portId - 20e00   Device PortId 20000   DeviceId 3     WWPN 
> 266000c0ffe03a3b
>   Lun   0   DISK  SUN     StorEdge 3510   327P
>                              
>   Device PortId 20500   DeviceId 1     WWPN 210000e08b0e4a5e
>
>
>   Device PortId 40655   DeviceId 6     WWPN 50060b0000204828
>   Lun   0   TAPE  HP      Ultrium 2-SCSI  K342
>
>
>
> /pci@1c,600000/SUNW,qlc@1
> *************************  Fabric Attached Devices  
> ************************
> Adapter portId - 10e00   Device PortId 10000   DeviceId 2     WWPN 
> 216000c0ff803a3b
>   Lun   0   DISK  SUN     StorEdge 3510   327P
>
>
>   Device PortId 10100   DeviceId 3     WWPN 226000c0ffa03a3b
>   Lun   0   DISK  SUN     StorEdge 3510   327P
>
>
>
>   Device PortId 30000   DeviceId 7     WWPN 500104f0006e4c90
>   Lun   0   CHANGER  STK     L180            0306
>
>
>   Device PortId 30655   DeviceId 8     WWPN 50060b0000204934
>   Lun   0   TAPE  HP      Ultrium 2-SCSI  K342
>
> At the OS level I type format and I only see the local drives
>
> # format
> Searching for disks...done
>
>
> AVAILABLE DISK SELECTIONS:
>       0. c1t0d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
>          /pci@1f,700000/scsi@2/sd@0,0
>       1. c1t1d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
>          /pci@1f,700000/scsi@2/sd@1,0
>       2. c1t2d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
>          /pci@1f,700000/scsi@2/sd@2,0
>       3. c1t3d0 <SUN36G cyl 24620 alt 2 hd 27 sec 107>
>          /pci@1f,700000/scsi@2/sd@3,0
>
> I have done this on other server that are V480 that work just fine, 
> but on the two V440's I can not see the storedge 3510
>
>
> Thanks
>

-- 

      0___      Wolfgang Schwurack
     c/  /'_    Unix System Administrator
    (*)  \(*)   University of Utah/Utah Education Network
                Tel: (801) 587-9444
                email: wolf@uen.org
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Fri Aug 6 10:21:12 2004