SUMMARY: Post Diag keeps looping

From: Bob Barkhymer <barkhymr_at_nosc.mil>
Date: Fri Jul 02 2004 - 07:23:57 EDT
Solution: And the winner is ......... Joe Kabbabe who suggested replacing
the clock board. Which I never thought could cause a problem like this even
though I had already narrowed the problem down to a few boards (clock, I/O,
disk) or the backplane.

Thanks to all


Original Question:

Good Morning Sun Managers,

I have a E4500 Server with Solaris 8 installed which will not boot up to the
ok prompt. It was working fine and somebody claims they just rebooted it. We
connected a laptop and ran in diagnostics and it seems looks like the post
diag keeps looping with no error messages. Any suggestions? Settings in
Printenv look okay.

Thanks,

Bob
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Fri Jul 2 07:24:21 2004

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:33 EST