SUMMARY: Diff SCSI Controller in Sun Fire 280R

From: Bhavesh Shah <bshah_at_citadon.com>
Date: Fri May 28 2004 - 15:49:22 EDT
Hi,
Thanks to all who replied especially
Tony Walsh
Anjan Dave
Pascal
>From whom I got the hint what to check for. Finally I figured it out.
The problem was Active termination Jumper on the Diff controller card
(SYMBIOS LOGIC - SYM 22802) was on (enabled). Disabled (Off) it and it
started working.

Thanks a lot and sorry if I missed anyone.
Bhavesh

My Original Question was:
--------------------------
Hi Gurus,

I have Sun Fire 280R Box where I have connected A1000 with PCI Diff SCSI
Controller in slot PCI2 and am getting following error messages while
booting:

And sits there forever.



WARNING: /pci@8,700000/scsi@3,1 (glm3):

        Connected command timeout for Target 3.0

WARNING: /pci@8,700000/scsi@3,1 (glm3):

        Target 3 reducing sync. transfer rate

WARNING: /pci@8,700000/scsi@3,1 (glm3):

        got SCSI bus reset

WARNING: /pci@8,700000/scsi@3,1 (glm3):

        Connected command timeout for Target 3.0

WARNING: /pci@8,700000/scsi@3,1 (glm3):

        got SCSI bus reset



The same A1000 I connect to E 3500 works fine where we have S-BUS Diff
SCSI controller.

The PCI Diff SCSI controller is new.

Any Help will be greatly appreciated.

Thanks

B
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Fri May 28 15:50:01 2004

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:31 EST