Thanks for the many replies. The problem is that the A1000 has a Differential (HVD) SCSI port while the Netra has a built-in UltraSCSI (SCSI-3) port. Solution: I need to acquire/install a X6541A Differential SCSI controller in the PCI slot of the Netra and terminate the A1000 with a (Sun Part #) 150-1890 terminator. -- John Bossert jbossert@unifiedsignal.com _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Tue Jan 6 13:35:23 2004
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:27 EST