SUMMARY: How to check fdx/hdx network status (fwd)

From: Jordi Vidal <jordivi_at_wtransnet.net>
Date: Thu Oct 16 2003 - 12:16:55 EDT
Thanks for the quick answer to:

Rob De Langhe        
Hargrave, Mark E
Davis, Uly 
Ximo Domenech    

	The way to check link speed (10/100) and Duplex mode (Full/half) 
is to get it from "ndd /dev/ce" parameters link_mode and link_speed.

ndd -set instance 0             (for ce0/hme0/whatever0)

Duplex Mode:
ndd -get /dev/ce link_mode
0 -> half
1 -> full

Link Speed:
ndd -get /dev/ce link_speed
0 -> 10 Mbps
1 -> 100 Mbps

I also get a response about use "netstat -k", but I thing the above is 
easier.

Regards,
	Jordi



-----Original Message-----
From: Jordi Vidal [mailto:jordivi@wtransnet.net] 
Sent: Thursday, October 16, 2003 5:28 PM
To: sunmanagers@sunmanagers.org
Subject: How to check fdx/hdx network status


Hi

	How can I know if my network card is working at 100Mbps fdx or 
100Mbps hdx?.

	I have no fisical access, so I cannot plug/unplug the UTP and tail
-f dmesg output.

	"ndd /dev/ce" reports "1" for all capabilities

Regards
	Jordi
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers


>>> 
30th Telindus International Symposium 
Thursday, October 30, 2003 - Brussels Expo, Belgium 

Check out the complete conference programme, exhibition, 
workshops and register now for this high value 'must attend' event! 

http://www.telindussymposium.com 
<<<
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Thu Oct 16 12:16:48 2003

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:22 EST