From: Felecia Diggs <FeleciaDiggs_at_schev.edu>
Date: Thu Jun 05 2003 - 11:40:31 EDT
Thanks to David Harrington for his response.     
Summary:    The drive is going or has gone bad.  Physically replace the
drive with another of the same drive type.  Until I do so, anything else
I do is futile. 

Original message posted follows:  
Scenario:  Solaris 2.6 system, using Solstice Disksuite to mirror
contents of one disk to another. Server Ultra Enterprise 3000  

Problem:  Half of my /, /usr, swap, /opt, /usr/openwin and /home
mirror
are in a state of "Needs maintenance".  All of these slices are on the
same internal sun drive.  I have tried to metareplace these submirrors
however, each fails with an I/O error such as the following:   
  
# ./metareplace -e d1 c1t0d0s0
metareplace: harrison.Schev.EDU: /dev/dsk/c1t0d0s0: I/O error

I received error messages on 5/26 and 5/27 but haven't received any
additional error messages since 5/27.  A sample of the error messages
follows below in bold.  My question is do I approach resolution to
this
as if I am recovering from a boot device failure (ex: replace the
disk,
format it, metareplace to enable the new submirrors) even though the
system is not and has not gone down?       

Thanks in advance for your input.   


May 26 06:22:17 harrison.Schev.EDU unix: WARNING:
/sbus@3,0/SUNW,fas@3,8800000/s
d@0,0 (sd30):^M^M
May 26 06:22:17 harrison.Schev.EDU unix:        Error for Command:
write(10)    
           Error Level: Fatal
May 26 06:22:17 harrison.Schev.EDU unix:        Requested Block:
2268016        
           Error Block: 2268016^M
May 26 06:22:17 harrison.Schev.EDU unix:        Vendor: QUANTUM       

        
           Serial Number: 97121D1696  ^M
May 26 06:22:17 harrison.Schev.EDU unix:        Sense Key: Hardware
Error^M
May 26 06:22:17 harrison.Schev.EDU unix:        ASC: 0x9 (<vendor
unique code 0x
9>), ASCQ: 0xee, FRU: 0x0^M
May 26 06:22:17 harrison.Schev.EDU unix: WARNING: md: d15: write error
on /dev/d
sk/c1t0d0s3
May 26 06:22:17 harrison.Schev.EDU unix: WARNING: md: d15:
/dev/dsk/c1t0d0s3 nee
ds maintenance
May 26 06:22:17 harrison.Schev.EDU unix: WARNING:
/sbus@3,0/SUNW,fas@3,8800000/s
d@0,0 (sd30):^M^M
May 26 06:22:17 harrison.Schev.EDU unix:        Error for Command:
write        
           Error Level: Retryable
May 26 06:22:17 harrison.Schev.EDU unix:        Requested Block:
1892176        
           Error Block: 1892176^M
May 26 06:22:17 harrison.Schev.EDU unix:        Vendor: QUANTUM       

        







Felecia F. Diggs
Unix Administrator
State Council of Higher Education for VA
(804) 225-2643
Email:  feleciadiggs@schev.edu
_______________________________________________
sunmanagers mailing list
sunmanagers@sunmanagers.org
http://www.sunmanagers.org/mailman/listinfo/sunmanagers
Received on Thu Jun 5 11:43:44 2003

This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:11 EST