Dear Managers, I'd like to thank Darren Dunham Rene Casalme Juergen Waiblinger for their answers in this matter. There were several issues/misunderstandings on my side that let to the post in the first place. After reading the answers on my post and thinking a little I got it working: 1) Of course I forgot to edit /kernel/drv7sd.conf, so when my array had initialized the new hd's as lun1, they wouldn't show up. 2) Solaris 8 (and 9, too?) does not handle devices with more than 1TB capacity. Even DiskSuite can't do anything about that. Since my array was slightly above that limit, I finally reinitialized the whole array (I had made a backup before...) and changed it into Raid5+spare, so that the final capacity was below 1TB. regards, Levent Original post: > Hi Managers, > > our group bought a TripleStor IDE-to-SCSI RAID system some while ago. > We could only afford to buy 5 hd's with it, so three slots remained unused. > That system works fine, after initialing the RAID system to RAID5, we just did > a format/partition/newfs and mounted it.... > Just recently, we decided to buy the "missing" three hd's, they arrived a few > days ago. After plugging them in and re-initializing the array, I have another > LUN available.... > But now I don't know how to procede. After rebuilding the /dev and /devices > links, the new disks to do not show up. I checked the existing partition with > 'format', it has still the original size. > I would like to merge both LUN's on the array, is this possible? Do I have to > use disksuite? --------------------------------------------------------------------- Levent Demiroers kaa.desy.de/people/Demiroers.html _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Mon May 19 11:57:51 2003
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:11 EST