Hi, Tentative summary this. It appears it was actually a bad DIMM. However there's a bug in the firmware such that it reports the wrong module as being faulty. Patches will follow naturally. I'm still curious as to why it was the disk traffic that provoked the error but presumably the copy operations exercised the specific location which had the fault. ------------ originally ------------------- Anyone got any ideas on this? System is a V880 fully packed patched upto 108528-18, OBP 4.7.0. It's almost certainly not an error in physical memory and we've had the DIMMs swapped out. Errors get clocked as soon as we start loading the disks. Looks to me like it might be a PCI issue but I'm open to suggestions. Cheers Joe _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Thu Apr 3 06:22:49 2003
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:43:08 EST