Hello! I got this message from lots of people: "Use prtdiag -v" The strange thing is that the output from prtdiag -v differ from the actual LEDs on the front panel. POWER SUPPLY ERROR says OFF but it is still yellow! Also a manual (http://sundocs.princeton.edu:8888/ab2/coll.240.2/UGJAVELIN/@Ab2PageView/idma tch(Z400037430C1)#Z400037430C1?) said that the General Fault LED should be yellow if any other fault has been detected. It is not yellow! I also got some replies with hints of what to do if there is an inconsistancy between LEDs and prtdiag -v output: The prtdiag command (/usr/platform/sun4u/sbin/prtdiag) should show you which component is faulty. I have had this happen on an E250 when I interrupted the boot process, when there was not actually anything faulty. The light stayed on, but there was no fault. The solution I used to get it to go out was to physically power it off, and then start it up again. This may not be an option, but if you can reboot the machine would be a useful test if prtdiag doesn't show an error. Run `/usr/platform/sun4u/sbin/prtdiag -v |more` This will identify any hardware problems you may have, with very few exceptions. If the wrench light remains orange and yet prtdiag does not report any problems, try running SunVTS or somesuch. If nothing comes up, call in Sun support. Many thanks to: Graham Wood [rauxon@dragonhold.org] Tommy.Fallsen@kongsberg.com Mike McShane [mcshane@cs.umn.edu] Matt D. Harris [mdh@mdh.si.edu] Bertrand_Hutin@notes.amdahl.com Steve Wills [steve@stevenwills.com] Bob Rahe [bob@dtcc.edu] Matthew SAMS [maclean@cs.mcgill.ca] VGunville@Lumenos.com Christophe Dupre [duprec@scorec.rpi.edu] /jonas > -----Ursprungligt meddelande----- > Fren: Jonas Bleberg > Skickat: den 7 maj 2002 08:32 > Till: 'sunmanagers@sunmanagers.org' > Dmne: HW error on my E250? > > Hello! > > I have an E250 where the front-end lamp marked with a "flash" symbol has gone orange. Both power supplies are showing two green lights. I have not found anything in the messages log (and syslog should be configured to put everything interesting there). Nothing is behaving strange in the machine. I installed an extra NIC two weeks ago, but it is working as it should. > > Which units are showing problems through the "flash" symbol on the front? > > Is there any way to find out which unit is erroneous? > > /jonas > > > > Jonas Bleberg > Cell Network Sverige AB > Kruthusgatan 17,6 > S-411 04 Gvteborg > jonas.blaberg@cellnetwork.com > @office: +46-(0)31-739 84 54 <----- Number has changed! > not@office: +46-(0)709-95 00 68 _______________________________________________ sunmanagers mailing list sunmanagers@sunmanagers.org http://www.sunmanagers.org/mailman/listinfo/sunmanagersReceived on Wed May 8 03:33:21 2002
This archive was generated by hypermail 2.1.8 : Thu Mar 03 2016 - 06:42:42 EST