Hello!
My original question:
>I have a SUn 450 and I will use raid 5 . In the tecnic specification
said this machine implement raid by hardware, Is this true?
>
Thanks at all!
Bill Armand, José Carlos Pérez Ramilo,John T. Douglass,
Vinay_Thakral, Birger Wathne , Bageshwar Kumar Sr.CSE, John Malick ,
Donelle Charles, Mohammad Matar , F.M. Taylor, Steve Widup.
Some answer are:
Not unless you have Sun's SRC/P hardware RAID controller. By default the
E450
does software RAID with Disksuite, etc but needs the SRC/P controller
for
hardware RAID
That is not true. Unless you get one of the CPI based hardware RAID
controllers. Without that, you could use Solstice Disk Suite or Volume
Manager.
Yes, hardware RAID 5 is an option but only if you have the correct SCSI
controller cards (DPT) installed and then only on the top two shelves
(16
disks total). The bottom four disks are always JBOD. The RAID
controllers
are an extra addition and may come separately. Their installation is a
little awkward also. Also be aware, some drives have seating issues on
the new drive plane and need to be pushed in a little harder then
regular.
Thanks!
-- ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Antonia Gomez Gonzalez FIB (Laboratori de Calcul) UPC Barcelona ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~S U BEFORE POSTING please READ the FAQ located at N ftp://ftp.cs.toronto.edu/pub/jdd/sun-managers/faq . and the list POLICY statement located at M ftp://ftp.cs.toronto.edu/pub/jdd/sun-managers/policy A To submit questions/summaries to this list send your email message to: N sun-managers@ececs.uc.edu A To unsubscribe from this list please send an email message to: G majordomo@sunmanagers.ececs.uc.edu E and in the BODY type: R unsubscribe sun-managers S Or . unsubscribe sun-managers original@subscription.address L To view an archive of this list please visit: I http://www.latech.edu/sunman.html S T