Thanks to Imre Kolos who gave me the correct answer.
the problem was that one of the power supplies( 0), was failed but the
messages show the power supply 1 as a damaged power supply.
Amparo Blanco wrote:
> hi managers
>
> i have a problem with an enterprise 450 , solaris 7 and recommended
> patches.
>
> init 5 causes the system to reboot, i know that there is a patch that
> fix this problem. Does anyone know it????
>
> thanks at all.
This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:14:01 CDT