My original message was:
We have an Sun Enterprise 450, a PCI based machine, with four A5000 storage
> arrays attached. Lately we have been getting the above message. We've
> swapped out literally all the hardware we can but to no avail.
>
> Any ideas? Any suggestions at all as to what the problem is and how to
sort
> it out would be appreciated.
>
> Thanks,
>
> Rezbi
I received a number of replies to this, all helpful as they made me think
about the problem. Unfortunately, I had to call in a Sun SSE in the end and
it turned out to be a dodgy FC-AL card.
Such an easy solution to what seemed to be an impossible situation. It
turned out that the FC-AL card that had been swapped in the first place was
dead-on-arrival.
Thanks to everyone who replied. Below are the names of people I would like
to thank:
Michael Brock
Phil Scarr
Rachel Polanski
Rajeev Kumar
And specifically Scott Clark, who asked for further info to help with this
problem. Sorry for not returning a reply to the last mail, Scott, it's been
hectic.
Cheers, everyone
This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:13:25 CDT