Thanks for all the people who asked me to look into the diag-switch?
variable setting. It was NOT set to true as most people thought. However,
thanks to the pointers
to this variable I read the OBP command reference manual and found
somethign suggesting that the same effect would be realized if a
machien ahd the "diagnostic switch" turned on.
Well guess what? The SPARCserver1000E has a key controlled 4 position
switch, and the switch happened to be in the "give diagnostics" position.
In this situation, it doesn't matter what the setting of
diag-switch? is the result is as if it were set to true anyway.
With OpenBoot 3.x there is a variable called diagnostic-mode? which
can be used in addition to determine what the "real" situation is.
Saurabh
-- _______________________________________________________________________________ . . Saurabh Jang ... ... E-mail : jang@eis.comm.mot.com Motorola, iDEN ..... ..... Voice : (847) 576-2630 1301 East Algonquin Road .. ... .. Fax : (847) 538-5564 Schaumburg, IL 60196 . . . Mail Drop : Building IL02, Room 3346 _______________________________________________________________________________