I had asked which internal disk had which SCSI target ID in an Ultra 2.
I already knew that the target IDs were 0 and 1, just needed to match them up
to the physical location of the disks.
The answer is that the disk facing the front is target 1, the disk facing the
rear is target 0. A useful suggestion was to simply pull one of them out and
try to boot off the current boot device. If the boot succeeded, the target ID
of the disk inside is that of the current boot device.
There sia slight difference for the Ultra 2 Creator series in that the drives
are not "left and right", but are on stacked up , i.e., are "up/down".
Saurabh
-- ______________________________________________________________________________ . . Saurabh Jang ... ... E-mail : jang@eis.comm.mot.com Motorola, iDEN Development ..... ..... Voice : (847) 576-2630 1301 East Algonquin Road .. ... .. Fax : (847) 576-3603 Schaumburg, IL 60196 . . . ______________________________________________________________________________