SUMMARY: Correction - Determination of Dump Parameters

From: Cathy Smith (csmith@dalsemi.com)
Date: Thu Feb 05 1998 - 10:18:43 CST


hi

this is a correction to my posting on 12/12/98 where i listed
the dump parameters to use for the compressed capacity of the
Exabyte 8705DX tape drive.

the correct parameters to use for 8 mm tapes are:

   1. 112m length tape
        density 54000
        blocks 126
        size 13000
   2. 160 length tape
        density 54000
        blocks 126
        size 17000

please note that the blocks parameter is not required.

i apologize for the error.

thanks

cathy

-- 
Cathy L. Smith
Dallas Semiconductor
(972)371-6720
e-mail: csmith@dalsemi.com