>It took awhile, but I finally got answers and here it is. The errors
>mean cpu5 is bad and needs to be replaced. So that's what
>we will do.
>
>Thanks to all who responded.
>
>Lisa
>
>
>Original message:
>
>>Can anyone tell me what these errors mean, or where there is a good
>>reference book to look them up.
>>
>>System: SunOS 5.3
>>
>>System panicked and rebooted last night. I didn't want to send
>>the whole file, so below are what I believe are the culprits.
>>
>>BAD TRAP: cpu_id=5 type=9 <Data Fault> addr f61f3d50 rw=1 rp=e6991564
>>MMU sfsr=0x5336:ft=<access Bus error> at= <supv data load> level=3
>>MMU sfsr=0x5336: <P,UC,FAV>
>>
>>PANIC [cpu5] thread=0xf7df1c00:Data Fault
>>WARNING: Board 2 Cpu B (cpu5) MXCC ERROR 0x0a3004400961cd00
>>MXCC.ERR=0xa300440<CP,EV,S>
>>WARNING: Ecache Parity error
>>
>>I am assuming something happened on CPU 5 but don't know exactly what,
>>and I am assuming MMU means Memory Module Unit.
>>
>>I will summarize.
>>
>>Lisa
>>
>
Lisa Yost
System Administrator
Los Alamos National Laboratory
667-8912 (office)
995-5335 (pager)
"Just another pane in the glass"
This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:11:51 CDT