SUMMARY: SparcStation Without A Monitor

From: Martin Jackson (martinj@ncp.gpt.co.uk)
Date: Wed Oct 23 1996 - 05:44:38 CDT


All,

Many thanks to the very many who responded and for the speed of the responses.

The general view was to make use of a terminal server to provide the
connectivity.

As far as connecting and disconnecting a terminal to a 'live' machine, the
key is to ensure that the power is left on the terminal when disconnecting
and connecting. This prevents the interrupt, which was where we were going
wrong.

The prom settings to check are :

         output_device
         input_device
         tty?_rts_dtr_off
         tty?_ignore_cd
         tty?_mode
         tty?_rts_dtr_off
         tty?_ignore_cd
 

Thanks again,

                Martin Jackson.
                Email: martinj@ncp.gpt.co.uk



This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:11:13 CDT