Original question:
>A problem occured with our diskless SLC. I tried to fix
>it and executed a memory test on monitor level.
>We had to change an EPROM. But something has remained
>set and the time consuming memory test is executed during
>every boot. Do you have any suggestions how could I switch
>it off ?
>
You can change the EEPROM parameters in two ways:
- on monitor level at the ok prompt by setenv
- from the operating system using the eeprom command
I had to change the diag-switch? parameter to false, e.g.:
ok setenv diag-switch? false
A very useful command to check what is set is printenv
at the ok prompt or eeprom without arguments in the
operating system.
Some people suggested to set the selftest-#megs parameter
to 0 or 1, but that was not a solution for my problem
(it was already set to 1 as default).
Many thanks to:
Bulent Ozunaldim <ozunal@Bilkent.EDU.TR>
Casper Dik <casper@holland.Sun.COM>
Ken Ferguson <ssa@pvdsw.amat.com>
Russ Poffenberger <poffen@San-Jose.ate.slb.com>
Adam Nevins <adam@ltx.com>
Rasana P. Atreya <Rasana.Atreya@library.ucsf.edu>
Benjamin Cline <benji@hnt.com>
Paulo Licio de Geus <paulo@dcc.unicamp.br>
Regards,
Michael