SUMMARY- SCSI differential drive

From: Rasana P. Atreya (Rasana.Atreya@library.ucsf.edu)
Date: Mon Mar 25 1996 - 11:47:14 CST


Hi!!

Thanks (a lot ;-) to

anderson@neon.mitre.org (Mark S. Anderson)
poffen@San-Jose.ate.slb.com (Russ Poffenberger)

for their responses. My original post and their responses follow.

Rasana
---------------------------------------------------------------------------
Hi!

I have SCSI differential drive from R-Squared. I tried to move this from one
machine to another (both Sparc 10 and SunOs 4.1.3_U).

I got the following message after each SCSI device on bootup:
runpoll-timeout on polling
  
I do not get these messages on the first machine. Does the second machine
need a differential cable? Is there anything else I am missing?

Also, I know that total cable length should not be "too long". How long is
too long?

I did make sure that:
Connectors are tight
Termination is okay

Thanks a lot for you help,
Rasana

---------------------------------------------------------------------------
From: anderson@neon.mitre.org (Mark S. Anderson)

You need a differential controller!

Mark Anderson

---------------------------------------------------------------------------
From: poffen@San-Jose.ate.slb.com (Russ Poffenberger)

A differential driver needs both a controller and a cable capable of
differential SCSI.

The SCSI connections built-in on all Sun's is non-differential.

~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
~ Rasana Atreya Voice: (415) 476-3623 ~
~ Programmer/Analyst Fax: (415) 476-4653 ~
~ Library & Ctr for Knowledge Mgnt, Univ. of California at San Francisco ~
~ 530 Parnassus Ave, Box 0840, San Francisco, CA 94143-0840 ~
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~