Hello Sun-Managers,
I got I/O-errors from Harddisk after connecting the HP 35480A DAT-Drive to a
Sun SPARCsation LX under Solaris 2.2
The likely poeple below told me, that such problems are caused by the
Fast-SCSI-Bus of the new Suns. They are much more sensitve to the lenght and
quality of the SCSI-Bus-Cable and terminators. Low quality will cause
timing-problems that are responsible for the I/O-errors. An very important
thing is to take an *ACTIVE* terminator. I had a passive one and I'll ordered
an active one.
Zdenek told me, that the HP35480A need a special setup for each
UNIX-Workstation. I checked this too. He also told about timing-problems on
SCSI-Bus.
Thanks to the following people:
Glenn Satchell (glenn@uniq.com.edu)
Martin Achilli (achillm@imihsra.bitnet)
Zdenek Dospisil (dannyd@mel4360.miden.com.au)
Thanks for advise!
Bye! | Goeran Jensen Wehlberg 10 D-24988 Oeversee
Goeran | Phone: +49-4630-356 priv. Phone: +49-4630-829
| Fax: +49-4630-357
| Internet: gj@sunshine.fido.de
This archive was generated by hypermail 2.1.2 : Fri Sep 28 2001 - 23:08:09 CDT